AWWA C950 PDF

AWWA C Fiberglass Pressure Pipe, Includes Errata (). standard by American Water Works Association, 01/20/ View all product details. ASTM D and AWWA C requirements. Strain Corrosion Testing. A unique and important performance requirement for GRP gravity pipe used in sewer. PIPE AWWA Cpdf – Download as PDF File .pdf) or read online.

Author: Zulkigami Mulrajas
Country: Burma
Language: English (Spanish)
Genre: Marketing
Published (Last): 12 August 2006
Pages: 282
PDF File Size: 13.50 Mb
ePub File Size: 11.93 Mb
ISBN: 510-3-75016-356-5
Downloads: 2773
Price: Free* [*Free Regsitration Required]
Uploader: Kizragore

Underground feeding GRP piping systems. Roving may be processed in a continuous or chopped form.

Fiberglass Pipe Conforming to Awwa C950 Standard

The manufacturer shall inspect one length per lengths of pipe before shipment for dimensions and tolerances outlined in Sec. Thus, users of this standard should consult the appropriate state or local agency having jurisdiction in order to 1.

The ID of the finished pipe is determined by the amount of material introduced into the mold. The minimum hoop tensile strength properties shall be determined from the average of the test results of three specimens cut from the sample when using the apparatus and procedure of one of the following test methods: If the document is awda or amended, you will be notified by email.

Flue gas desulphurisation 4. Service and distribution piping systems and transmission piping systems are included. A filled or unfilled thermoplastic or thermosetting resin layer, nonreinforced or reinforced, that forms the interior surface of the pipe.

AWWA C950 SPECIFICATIONS FOR FIBERGLASS PRESSURE PIPE

For example, f950 4 percent long-term Table 8 Minimum pipe stiffness requirements for 5 percent deflection Stiffness Class—psi kPa Nominal Pipe Size 9 62 18 36 72 in. To ensure compliance, the following tests shall be performed at the indicated intervals, unless otherwise specified by the purchaser.

Pipe diameters and swwa shall be as shown in Tables 1, 2, 3, 4, 5, and 6 when measured in accordance with ASTM D Rejection should be reported to the manufacturer or supplier promptly and in writing. Send your message to this supplier. The person, company, or organization that purchases materi- als or work to be performed.

  ESTUDIO DE PNEUMATOLOGIA PDF

A joint that is not capable of axial displacement or angular rotation. Enter the email address you signed up with and we’ll email you a reset link.

AWWA C – Fiberglass Pressure Pipe

A fiberglass pipe with aggregate. Materials shall comply with the requirements of the Safe Drinking Water Act and other federal, state, and local requirements. Any of a class of solid or pseudosolid organic materials, often of high molecular weight, with no definite melting point. ANSI procedures require that action be taken to reaffirm, revise, or withdraw this standard no later than five years from the date of publication. This test pressure shall be maintained for at least 30 sec.

Special preparations needed for shipment Sec. Specific service and installation considerations. Use of Annex A procedures may not always be identical, depending on the certifier.

In method 1, the pipe shall withstand, without failure, the beam loads listed in Table 12 when v950 in accordance with the beam-strength test method of ASTM D AWWA publication of a standard does not constitute endorsement of any product or product type, nor does AWWA test, certify, or approve any product. Upper Limit Lower Limit 04 The manufacturer shall perform axial tensile strength tests at a frequency of one test for each c590 of pipe produced or from each manufacturing run, whichever provides the most frequent sampling of each class and size.

AWWA standards describe minimum requirements and do not contain all of the engineering and administrative information normally contained in specifications.

Producers of goods wwwa in conformity with an American National Standard are encouraged to state on their own responsibility in advertising and promotional materials or on tags or labels that the goods are produced in conformity with particular American National Standards.

The third edition was approved on Jan. The permissible adhesive-bonded awwx are as follows: You Might Also Like. Fiberglass pipe intended for use in the transport of potable water swwa be evaluated and certified for this use as required by the local authority.

  LOCOMOTION JACQUELINE WOODSON PDF

Pipe joints capable of withstanding internal pressure but not longitudinal tensile loads. Liner materials incorporated include thermosetting or thermoplastic resin, reinforced or c590 forced, with or without fillers. Reinforced polymer—mortar pipe RPMP: Affidavit of compliance Sec. American National Standard An American National Standard implies a consensus of those substantially concerned with its scope and provisions.

The nominal stiffness of a specified pipe. If a manufacturer desires to exclude inspection of proprietary manufacturing processes, the manufacturer shall so advise the purchaser. As the voice of the U. You may delete a document from your Alert Profile at any time. Use of This Standard.

The test data should be statistically extrapolated to establish strength at 50 years. Glass-fiber-reinforced polyester RTRP polyester.

China Fiberglass Pipe Conforming to Awwa C Standard – China Fiberglass Pipe, GRP Pipe

Process GRP piping systems. A glass-fiber fabric reinforcing material made by the weaving of glass-fiber roving. The Standards Council authorized the formation of the Standards Committee on Thermosetting Fiberglass Reinforced Plastic C50 in Octoberand committee organization was completed in December Except in cases of disagreement, routine quality control tests may be performed at ambient conditions of temperature and cc950, and calculations need not include the standard deviation.

The pipe shall show no visual awws of weeping or leakage. The pipe stiffness test specimen may be used for these tests. AWWA has no responsibility for the suitability or compatibility of the provisions of this standard to any intended application by any user.

The classes may need to be reduced for use at temperatures greater than